Honeywell MAXPRO-Net Commissioning Manual page 71

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

Source
Available
Control
Control,
Cont.
Cont.
Control
The source controls of a PTZ camera site (or VCR etc.) can be locked to prevent user
Locked
control of the device. The default lock/unlock status is specified here.
Note: This locked status can be unlocked by the system operator (if they have the
necessary System Access Level) from the MAXPRO-Net Menu System (using MaxMon).
Source
When a video input needs to be temporarily removed from the video input selection
Disable
table, the SOURCE DISABLE field would be set to YES. While set, the video input device
CANNOT be selected by any operator. Under normal operation this field is 'NO'. To
disable a particular video input device, a 'YES' is specified in this field. Enter Y or N in
this field and press Enter on the keyboard.
The SOURCE DISABLE state can be changed (using macro programming) while the
system is in operation e.g. [C123=T] or [C123=F] or through MaxMon.
Rev. B
Video Inputs, Continued
VCR, Logging VCR, Standby VCR:
S .. stop
R .. record
P .. play
E .. tape eject
W .. rewind/review
L .. slow
U .. pause
Standard Device, Smart Device:
For DDEV and SDEV control functions the enable flags are
displayed as numbers 1 to 8. This is because these devices can only
be controlled by using the macro method of executing direct control
functions for a device.
Ex: [Q123=^8] Refer to the macro programming manual for further
details.
6-9
F .. fast-forward/preview
HMXMC001013