Honeywell MAXPRO-Net Commissioning Manual page 113

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

Default Test
Mode
Printer Fail
Macro
Auto Message
Timeout
Rev. B
Special Parameters
The MAXPRO-Net Server has a video output, known as the menu output,
which usually displays the System Configuration Summary. During
system commissioning, it can be useful to default this menu output to
one of the system test modes. A pull-down menu displays the available
options. The options are described below.
Normal – displays the system Configuration Summary.
Rx data – displays the data received on all the MAXPRO-Net Server
serial communication ports.
TX data – displays the data transmitted from all the MAXPRO-Net
Server serial communication ports.
Execute Macros – displays all the macro sequences executed by the
system.
Macro Trails – displays the macro trail of the executed macro
sequence on the screen.
Error log – displays all subsequent entries to the error log file on the
screen.
Printer – displays all subsequent output to the hard-copy printer on
the screen.
Video Select – displays every video switching action in the system.
Control – displays every control action for PTZ cameras, VCRs etc.
Auto Number – No data is displayed on the menu output in this test
mode. However, if this mode is selected, description text displayed
on video output devices will show the logical device number of the
device at the start of the text line.
Click on the desired selection in the pull-down menu.
Note: When the system is running, the menu output can be
selected to display any of the test modes by selecting ALT-F1 to
ALT-F10 on the QWERTY keyboard.
This System Menu can also be seen using MaxMon utility in
MAXPRO-Net.
When the MAXPRO-Net Server detects the hard-copy printer is no longer
on line, the Printer Fail Macro sequence will be executed.
Please refer to the MACRO GUIDE for more details on the macro
functionality.
Enter the desired macro and press the Enter key on the keyboard.
This field defines the time period in seconds that the automatic message
line text is displayed. Valid values are 2 to 99 seconds.
Enter the desired value and press Enter on the keyboard.
6-51
HMXMC001013
31-Mar-06

Advertisement

Table of Contents
loading

Table of Contents