Casio DT-800RF Supported Equipment Manual page 46

Table of Contents

Advertisement

Error Message Resolution Guide
Message
User Count Exceeded.\n Session
Ended;
Primary Unavailable\nTrying Alternate; First Host IP address not available
APMAC.DAT Error\nSession Ended;
MUIP.DAT Error\nSession Ended;
Missing Subnet IP\nSession Ended;
Error Opening File;
Telnet API\nnot found;
Battery Low Warning\n\nReplace
Battery Soon;
No Host List.\nPress any key\nTo Edit
Host IP's;
Unable to Allocate\nFont Memory;
4-6
Reason
Possible authorization issue.
trying the remaining addresses in
the Host list.
Access point Media Access Control
error.
Mobile Unit IP Error.
Mobile Unit IP Netmask Error.
File is missing.
Program files are missing.
Not enough power to operate the
Mobile Unit.
Have not configured your target
hosts.
Mobile Unit does not have enough
memory to load the fonts.
Solution
Verify that you have the correct number of
licenses for the number of Mobile Units you
are using.
Verify the host address.
Most likely a range, access point, radio,
host or network issue. Troubleshoot the
customer's environment.
Most likely a Mobile Unit network setting
issue. Troubleshoot the customer's
environment.
Most likely a Mobile Unit network setting
issue. Troubleshoot the customer's
environment.
Verify that the configuration files are on the
Mobile Unit. Or perhaps there is a
hardware failure.
Reload program files.
Replace the battery with a fully recharged
battery.
Configure the target host IP addresses.
Reduce the fonts in use or expand the
memory in the Mobile Unit.
Supported Equipment Manual
Reference Tech Note
---
---
T1113, T1114, T1161,
T1171, T1187 and
T1194
T1113, T1114, T1161,
T1171, T1187 and
T1194
T1113, T1114, T1161,
T1171, T1187 and
T1194
---
---
---
---
---
• March, 2006

Advertisement

Table of Contents
loading