7.1.4.2 Selective Read RD

Start the reader with the command RD plus Parameters ( plus <CR>). see example
below.
- You can read out one block of the transponders memory, if the address of only one
. block is sent to the reader.
– You can read out several blocks, if the first and the last block to read is sent to the
reader. So it's also possible to read out the whole memory of the transponder.
Wait for the answer
Analyse the received answer: 8 characters plus <CR>. Allowed characters 0 to F.
The NoRead Code is set to ( „XXXXXXXX") ..
The result of the reading process may also be seen at the LED's.
LED L2 lit, if there was a successful read.
LED L3 lit, if there was a No Read.
Example
Allowed Values (block numbers of the transponder IC):
ALGO 9 (1kBit Memory)
ALGO 6 (2kBit Memory)

7.1.4.3 Writing Process WD

The memory of the transponder is organised in blocks, containing 32 bits. The data's of every
single block must be changed separately.
Start the reader with the command WD plus Parameters ( plus <CR>). See also example
below.
The sent parameter consists of the block address and writing data's (8 ASCII characters).
Note! There must be a blank between the block address and the writing data's..
RD <SP> 20 <CR>
RD <SP> 16 <SP> 33 <CR>
Serial Number
Serial Number
read block 20
read all blocks from 16 to 33
3 .... 33
block 32
16 ... 63
block 1