4.3.5 Final Assembly of the Cable Pipe

• Pull by and by all the cable back, until the isolation of the cables are near to beginning of
the cable pipes.
• Fasten nuts (5) of the cable pipes with the right tool (17mm).
• Do this carefully, to ensure the tightness of the protection class of IP 65..
• Plug the finished assembled MINI-COMBICON-Connector to the SAB Cab. Take care of
the correct coding ((7) in Figure 4-2) of the connectors.

4.3.6 Plug in of the SAB Cab

Attention:
Before plugging the SAB Cab to the connectors of the reader, make sure that the
grounding of the device is well done. Otherwise the electronic may be destroyed by elec-
trostatic discharge (ESD).
B
Figure 4-3: Plug on the SAB Cab
• Put on the sealing 2 to the SAB Cab (A).
• Plug in the SAB Cab to the connector at the bottom of the reader device (B).
• There is only one way to plug in the SAB Cab to the connector rim of the reader.
• Fasten the SAB Cab with the help of the screws.
A
1
2
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: info@AEGID.de