ISO 15693:
The reader answers the UID of a transponder. The length of the UID can be between 4 and 8 bytes.
Input format:
Output (example):
5.4.3 HD – halt detected code
The command HD mutes the last selected transponder.
Input format:
Output (example):
5.4.4 MD – mode of operation
There a two modes of operation available. It is possible, that the reader reads constantly or triggered by
an instruction.
Input format:
Output (example):
Parameter:
PARAMETER
0
2
5.4.5 RD – read page
With the command RD you can read out a page of the transponder. The command executes internally the
commands get tag, if using mifare 1K/4K log in (with the key attuned to KM) and the reading command.
Input format mifare 1K/4K:
Input format ultralight:
--------------------------------------------------------------------------------28/50--------------------------------------------------------------------------------
anticollision level 2
select 2
inventory
GT <CR>
625E562A <CR>
HD <CR>
ACK <CR>
MD <SP> parameter <CR>
2 <CR>
FUNCTION
constant reading mode
single reading mode
RD <SP> parameter 1 <SP> parameter 2 <CR>
RD <SP> parameter 2 <CR>