ARE I2 / RS 232 – Installation Guide

4.3.3 Mounting of the Power Supply Cable

The power supply cable must be mounted in following steps:
• Remove all inner parts from the cable pipe at the SAB Cab (1) ( nut (5), pipe(4) and cable
fastener (3)) (see Figure 4-2)
• Put all the removed parts ( nut (5), pipe (4), cable fastener (3)) and the cable pipe of the
SAB Cab as well (1 to 4) to the cable.
Figure 4-2: Arranged Parts for Mounting
• Remove the outer isolation of the cable at a length of 6cm .
• Remove the isolation of the wires at a length of 6 [mm] and stick a covering hull to the litz
wire.
• Put the cable to the cable pipe. The length of the cable coming out the SAB Cab must long
enough to do all further installation steps in an easy way.
• Stick the pipe (4) into the cable fastener (3).
• Stick the cable fastener (3) into the cable pipe.
• Connect the power supply cable into the right places of the MINI-COMBICON-Connector
(see Figure 4-2 Part (6)).
• The pin assignment is shown in the figure below.