The minimum voltage at the readers input mustn't be lower then 9V.
The maximum length of the serial RS232 cable is 15m.

3.3.3.1 Assembling of the cable pipe

Breakthrough the prepared areas at the surface of the SAB Cabs. There are two prepared areas seen
at the SAB Cab: central and at one side of the cab.
The o-ring (3) has to be assembled proberly to the cable pipe (4) to ensure the protection class IP
65.
2
Figure 2: Assembling of the cable pipe
Bring the nut (2) of the cable pipe inside of the SAB Cab (1).
To fasten the nut please use the right tool (17mm).

3.3.3.2 Mounting of the cable

The cable must be mounted in following steps:
Remove all inner parts from the cable pipe at the SAB Cab (1) ( nut (5), cable fastener (3), pipe(4))
(see Figure 3)