Wayne-Dalton 800FR Installation Instructions Manual page 16

Face mounted rolling steel storm shelter door with non-tension release automatic closure governor controlled
Table of Contents

Advertisement

Operator Install (continued)
12. WALL MOUNT
The Operator can be purchased for right-hand or left-hand
mounting for Wall Mount configuration. Right hand mounting
shown. Left hand mounting is a mirror image.
• Determine location for operator above or below door
shaft.
• Mark mounting holes on wall using template as a guide.
See Figure 20
• Install appropriate bolts or lag screws with washers to
wall leaving a 1/2" gap to slide mounting brackets onto.
(See chart)
• Hang operator to wall on adjustable mounting holes/hardware. See Figure 21
• Install door sprocket and key to door shaft, do not tighten.
• Install operator sprocket and key to operator output shaft, do not tighten.
• Align sprockets and install chain.
• Adjust operator and align shafts. Operator and door shafts must
be parallel for proper operation.
• Adjust operator as needed and tighten mounting hardware.
• Install appropriate
bolts/lags into at
JAMB FASTENER SPECIFICATIONS
least 2 lock down
Steel jambs must be minimum 3/8" thick
holes. See Figure 20
• Apply locking
Drill hole at least 4" from jamb corner per
OHD Installation Instruction 307390.0001.
compound to
Drill hole at least 4" from jamb corner per
door and operator
OHD Installation Instruction 307390.0001.
sprocket set screws
Drill hole 3" deep
and tighten.
Install 3" O.D. steel washer on opposite side
of wall.
830872-0001
REV 12/07/2022
Steel
Concrete
8-5/8"
6"
10"
Adjustable
Mounting
Holes
Lock
Down
Right Hand
Holes (4)
Fig. 7
Figure 20
©Copyright 2022 Wayne Dalton, a division of Overhead Door Corporation
onto. (See chart)
4) Hang operator to wall on adjustable mounting holes/hardware. Fig. 8
5) Install door sprocket and key to door shaft, do not tighten.
6) Install operator sprocket and key to operator output shaft, do not tighten.
7) Align sprockets and install chain.
8) Adjust operator and align shafts. Operator and door shafts must be parallel for proper o
9) Adjust operator as needed and tighten mounting hardware.
JAMB
FASTENER
10) Install appropriate bolts/lags into at least 2 lock down holes. Fig. 7
11) Apply locking compound to door and operator sprocket set screws and tighten.
1/2" self-tapping screw
JAMB
FASTENER
Steel
1/2" self-tapping
27/64" diameter
1/2" expansion bolt
screw
Concrete
1/2" expansion bolt
1/2" diameter
Filled block
1/2" expansion bolt
1/2" diameter
Wood
1/2" lag screw
3/8" diameter
Unfi lled
1/2" thru bolt
9/16" diameter
block
DRILL SIZE
JAMB FASTENER SPECIFI CATIONS
27/64" diameter Steel jambs must be minimum 3/8" thick
DRILL SIZE
JAMB FASTENER SPECIFICATIONS
Drill hole at least 4" from jamb corner per
Steel jambs must be minimum 3/8" thick
1/2" diameter
WD Installation Instruction 500460.0001
Drill hole at least 4" from jamb corner per
OHD Installation Instruction 307390.0001.
Drill hole at least 4" from jamb corner per
OHD Installation Instruction 307390.0001.
Drill hole 3" deep
Install 3" O.D. steel washer on opposite side
of wall.
Figure 21
Fig. 8
8-5
6"
Right Hand
Fig. 7
16

Advertisement

Table of Contents
loading

Table of Contents