Wayne-Dalton 800FR Installation Instructions Manual page 12

Face mounted rolling steel storm shelter door with non-tension release automatic closure governor controlled
Table of Contents

Advertisement

Operator Install (continued)
Safety Information & Instructions
1. Read manual and warnings carefully.
2. Keep the door in good working condition. Periodically lubricate all moving parts of door.
3. If door has a sensing edge, check operations monthly. Make any necessary repairs to keep it functional.
4. AT LEAST twice a year, manually operate the door by disconnecting it from the operator. The Door should open and close freely. If it does not, the door
must be taken out of service and a trained service representative must correct the condition causing the malfunction.
5. The Operator Motor is protected against overheating by an internal thermal protector. If the motor protector is tripped, a trained service technical may
be needed to correct the condition which caused the overheating. When the motor has cooled, thermal protector will automatically reset and normal op-
eration can be resumed.
6. In case of power failure, the door can be operated manually by pulling the release cable to disconnect the operator drive system.
7. Keep instructions in a prominent location near the Release Handle.
9. CRITICAL INSTALLATION INFORMATION
TECHNICAL DATA
The following information will help the installer and electrician fully
understand all aspects of this installation.
This unit contains the following parts:
- Operator assembly.
- Owners manual and warning/caution placards.
- Hardware box.
- 3-button control station.
- Drive Chain. #50
• Output Shaft Speed: 46 RPM
• Motor is continuous duty type
• Control wiring: Maximum of 1000 feet of 22-24 ga. stranded wire run.
830872-0001
REV 12/07/2022
IMPORTANT
READ PRIOR TO ANY DOOR OPERATION
©Copyright 2022 Wayne Dalton, a division of Overhead Door Corporation
Section 3: Critical Installation Information
Technical Data
The following information will help the installer and electrician fully understand all aspects of t
installation.
This unit contains the following parts:
Operator assembly.
Owners manual and warning/caution placards.
Hardware box.
3-button control station.
Drive Chain. #50
Output Shaft Speed: 46 RPM
Motor is continuous duty type
Control wiring: Maximum of 1000 feet of 22-24 ga. stranded wire run.
Electrical Load Information:
Amperage draw in Full Load Amps (FLA)
1 Phase 1/2HP Operators:
115VAC - 60Hz - 10 FLA
208VAC - 60Hz - 5 FLA
230VAC - 60Hz - 5 FLA
1 Phase 3/4HP Operators:
115VAC - 60Hz - 11 FLA
208VAC - 60Hz - 6 FLA
230VAC - 60Hz - 6 FLA
1 Phase 1HP Operators:
115VAC - 60Hz - 14 FLA
208VAC - 60Hz - 7 FLA
230VAC - 60Hz - 7 FLA
3 Phase 1/2HP Operators:
208VAC - 60Hz - 3 FLA
230VAC - 60Hz - 3 FLA
460VAC - 60Hz - 3 FLA
575VAC - 60Hz - 2 FLA
3 Phase 3/4HP Operators:
208VAC - 60Hz - 3 FLA
230VAC - 60Hz - 4 FLA
460VAC - 60Hz - 3 FLA
575VAC - 60Hz - 2 FLA
3 Phase 1HP Operators:
208VAC - 60Hz - 4 FLA
230VAC - 60Hz - 4 FLA
460VAC - 60Hz - 3 FLA
575VAC - 60Hz - 2 FLA
12