D
H1
Height back
H2
Height
H3
Height front
W
Width
D
Depth
M1
Mounting hole distance
M2
Mounting hole distance
Free space requirements
Frame
All
1) Drives with the optional UL Type 1 kit: 50 mm (2 in), measured from the top of the hood.
2) A side-mounted option module requires 20 mm (0.8 in) of free space on the right side of the drive.
Losses, cooling data and noise
Drives with frame size R0 have natural convection cooling. Drives with frame size
R1...R4 have a cooling fan. The air flow direction is from bottom to top.
IEC type
Typical power loss
ACS480-04-
1-phase U N = 230 V
02A4-1
33
03A7-1
49
04A8-1
67
06A9-1
93
1)
Above
mm
in
75
3
1)
W
BTU/h
113
167
229
317
W
Ø 5 [.21]
Ø 10 [.40]
Ø 5 [.21]
Free space requirement
Below
mm
in
75
3
Air flow
m 3 /h
CFM
-
-
-
-
57
33
57
33
Technical data 151
M1
M2
2)
Sides
mm
in
0
0
Noise
Frame
size
dB(A)
< 30
R0
< 30
R0
63
R1
63
R1