Table 23 - Information Menus - Honeywell SMV800 SmartLine User Manual

Multivariable transmitter
Hide thumbs Also See for SMV800 SmartLine:
Table of Contents

Advertisement

<Return> Return to the Level 1 menu
<Return>
Display
Firmware Version
<Return>
Firmware Version
Comm
Software Rev
Module
Protocol
<Return>
Firmware Version
Model Key
DP LRL
DP URL
DP Units
Meter Body
(in preferred unit)
SP LRL
(in preferred unit)
SP URL (in
preferred unit)
SP Units
(in preferred unit)
<Return>
Firmware Version
Model key
(Modbus only)
Temp LRL (in
preferred unit)
Temp Module
Temp URL (in
preferred unit)
Temp Units
(preferred unit)
Universal Temp
Flow Output
(Modbus only)
Options ***
Serial number
License Key
Revision 10
Table 23 – Information Menus
The firmware version of the Display Module
The firmware version of the Comm Module
The software revision of the Comm Module
The communications protocol of the transmitter:
HART: HART protocol
DE: Honeywell DE protocol
Modbus: Modbus protocol
The firmware version of the Pressure Module
Identifies the type and range of the transmitter
The Lower Range Limit of the DP
The Upper Range Limit of the DP
The Engineering Units for the LRL and URL.
Note that you can change these Units from the
Transmitter Setup menu, if desired (Transmitter
Setup\Parameters\Units)
The Lower Range Limit of the SP
The Upper Range Limit of the SP
The Engineering Units for the LRL and URL.
Note that you can change these Units from the
Transmitter Setup menu, if desired (Transmitter
Setup\Parameters\Units)
The firmware version of the Temperature Module
Identifies the type and range of the transmitter
The Lower Range Limit of the Temp
The Upper Range Limit of the Temp
The Engineering Units for the LRL and URL.
Note that you can change these Units from the
Transmitter Setup menu, if desired (Transmitter
Setup\Parameters\Units)
Universal Temp allows the user to see whether
or not they have an SMV unit that has the
optional TC temperature sensor types available
Flow Option allow to see user whether Flow
and Totalizer is enabled or not.
The serial number of the device that is
necessary for the user to obtain a license key
to enable Universal Temp option.
License Key is necessary for a user who
purchased the Universal Temp option to enable
the Universal Temp, giving access to TC
temperature inputs
SMV800 Transmitter User's Manual
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read/Write