Connecting Control Outputs; Control Outputs; Looping Output Termination - Honeywell MAXPRO NVR 3.1 Installation Manual

Table of Contents

Advertisement

Looping Output Termination

Connecting Control Outputs

MAXPRO NVR 3.1 Commissioning and Installation Guide
If the image appears distorted or virtually un viewable, turn the termination resister to ON
position, it means terminated. When it is necessary to terminate a looping output, the NVR has
built in termination that allows users to select individual outputs. It is not always necessary to
terminate the output; it depends on the device to which you are connecting. As a rule, if the
image appears distorted or virtually un viewable, it likely needs to be terminated.
Note:
Please refer to the specific Hybrid unit data sheet for more information on number
of looping outputs supported on a specific unit.
Figure 2-11
Looping Output Termination
Note:
Always leave the dipswitch set to the ON position when the Looping Outputs are
not used and only the installer should decide to turn it ON /OFF.
Each NVR Hybrid has Control Outputs. These outputs can be used to trigger devices such as
Sirens, Phone Dialers, Lights, and any other relay activated device. There is no power
supplied to the ports. Use an external power supply if necessary.
Figure 2-12

Control Outputs

S E T T I N G U P T H E M A X P R O N V R
MAXPRO NVR Hybrid Connections
35