Functional Description - Makita CW004G Instruction Manual

Cordless cooler & warmer box
Hide thumbs Also See for CW004G:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
NOTE: The control temperature is approximate.
Current temperature may repeat going over and
below the control temperature. This is because the
appliance turns on and off the cooling/heating oper-
ation to bring the temperature closer to the control
temperature.
The difference between the current temperature and
control temperature may increase depending on
usage condition, operation settings, and the things
you put in the appliance.
NOTE: The current temperature may not reach the
control temperature depending on the usage environ-
ment (extremely hot/cold), etc.
NOTE: The appliance keeps the temperature
when the current temperature reaches the control
temperature.
NOTE: Once the compressor stops, the compressor
does not restart for 3 minutes to protect itself.
NOTE: When operating the appliance in high humid
environment, dew condensation may occur on the
appliance. This is not malfunction of the appliance.
Use a dry cloth to wipe the dew condensation off the
appliance.
NOTE: During cooling operation, you may hear the
sound of water flowing from inside the appliance. This
is not malfunction of the appliance. This is the sound
of refrigerant flowing inside of the appliance to cool
the chamber.
Single chamber mode
In the single chamber mode, the temperature display
becomes as shown in the figure. The appliance cool/
heat the entire chamber to the control temperature.
► Fig.10
Dual chamber mode
In the dual chamber mode, the temperature display
becomes as shown in the figure. You can set the tem-
perature for left chamber and right chamber separately.
► Fig.11
You can also choose not to set the temperature by
pressing the setting button
shows " - - " if the chamber does not have the control
temperature.
NOTICE:
In the dual chamber mode, you can-
not set the control temperature if there is a 30°C
(55°F) or more difference with the other chamber.
An error tone will sound if you try to set the tem-
perature of such difference.
. The temperature display
FUNCTIONAL
DESCRIPTION
Indicating the remaining battery
capacity
The battery indicator shows the remaining battery
capacity. The remaining battery capacity is shown as
the following table.
► Fig.12: 1. Battery cartridge 2. Battery indicator
Battery indicator status
(Blinking)
NOTE: The error code "F2" is displayed on the tem-
perature display just before the appliance stops due
to running out of the battery.
(Only for battery cartridges with the
indicator)
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
► Fig.13: 1. Indicator lamps 2. Check button
Indicator lamps
Lighted
15 ENGLISH
Remaining
capacity
50% to 100%
20% to 50%
0% to 20%
Charge the battery.
Off
Blinking
malfunctioned.
Remaining
capacity
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have

Advertisement

Table of Contents
loading

Table of Contents