Honeywell 04230-A-1001 Technical Handbook page 121

Searchline excel infrared gas detectors
Table of Contents

Advertisement

MAN0530 Issue 15 - 07/17
2104M0506
APPENDIX D - MARINE BRACKET
Notes:
1. Drawing is NOT to scale.
2. U-bolts are NOT provided.
Identify
A
B
C
D
(2) Fit the vertical adjustment assembly to the main plate with 2 screws (M8x18) using mounting
holes B. Mount 2 hexagon socket screws to the vertical adjustment assembly but do not tighten
fully.
(3) Fit the pivot to the mounting plate and tighten it with a screwdriver.
(4) Fit the mounting bracket to the main plate with 4 screws (M10x20) using mounting holes C,
spring washers and washers but do not tighten fully.
(5) Tighten the 2 hexagon socket screws of the vertical adjustment assembly until they contact
the lever of the mounting bracket.
(6) Tighten the screws of the mounting bracket.
(7) Fit the pivot block to the mounting bracket using a nut, spring washer and washer (M12).
Do not tighten fully.
(8) Fit the Excel to the pivot block.
The correct orientation for the pivot and main support is as follows:
(9) Fit 2 screws (M8x25), 2 spring washers and 2 washers to the pivot block. Do not tighten
fully.
(10) Fix the horizontal position of the pivot block using 2 hexagon socket screws (M6x20).
Quantity
Size
4
9mm
2
M8
4
M10
1
M12
Used For
U-bolts (2 off)
Vertical Adjustment Assembly
Mounting Bracket
Pivot
121