Honeywell 04230-A-1001 Technical Handbook page 119

Searchline excel infrared gas detectors
Table of Contents

Advertisement

MAN0530 Issue 15 - 07/17
2104M0506
APPENDIX D - MARINE BRACKET
D.2.2 Installation Procedure
D.2.2.1 General
The Marine Bracket is to be used in installations where compliance to the DNV Maritime
Standards are required. The bracket is supplied as part of a specific Searchline Excel kit for
this application.
To ensure full compliance with the DNV standard, do not modify or interchange parts from the
standard Searchline Excel brackets and carefully follow the instructions contained within in
this section.
D.2.2.2 Mechanical Installation
The mechanical installation procedure applies to both the Receiver and the Transmitter.
NOTE: THIS BRACKET IS DESIGNED FOR USE WITH THE SEARCHLINE EXCEL
SHORT-RANGE SYSTEM ONLY. DO NOT ATTEMPT TO MOUNT MEDIUM-RANGE
OR LONG-RANGE TRANSMITTER UNITS USING THE MARINE BRACKET.
(1) Fit the mounting plate to a single pipe or pole as shown: The pole should be between 100mm
and 150mm in diameter (4" and 6").