Honeywell CT47 Series User Manual page 49

Hide thumbs Also See for CT47 Series:
Table of Contents

Advertisement

Setting
Data Intent
Symbology Settings
Use the Symbology Settings to enable or disable barcode symbologies for the
selected scan setting profile.
To view a list of default settings for supported symbologies, see
Symbologies
Decode Settings
Adjust the Decode Settings when scanning barcodes that are densely packed or
poor quality.
Decode Settings
Setting
Center Decode
Decode Security
Decoder timeout
CT47 Mobile Computer Series User Guide
Description
Enables the reception and processing of barcode data
without using an SDK or library.
Tap the check box next to a symbology name to enable (check mark) or disable
(no check mark) decoding for that symbology.
Tap the symbology name to view and modify additional configuration
parameters for the symbology selected.
on page 102.
Description
When enabled, the imager scans and decodes a barcode only
if part of the barcode is at the center of the aimer window. This
is useful in situations where several barcodes may be very
close together in the imager field-of-view.
Honeywell recommends leaving the window size settings at 50
(default) to define the "center" area for the barcode.
Configurable parameters:
Use this setting to control the reading tolerance of the
decoder. Lower settings are more lenient when reading low
quality barcodes while higher values are more strict.
Set the amount of time in milliseconds that the scanner will
timeout if a readable barcode is not found.
Tap the check box to toggle the feature On or Off.
Select Center Decode to adjust the feature
parameters.
Center Decode Timeout (ms)
Window top
Window bottom
Window left
Window right
Default
Disabled
Barcode
Default
Disabled
2
150
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct47xonCt47xinCt47x0nCt47x1n

Table of Contents