Setting Fence Stops

The fence stops simplify the task of adjusting the
fence to 45° inward, 90°, and 45° outward (135°).
Tools Needed
45° Square ........................................................ 1
90° Square ........................................................ 1
Sliding Bevel ...................................................... 1
Open-End Wrench 10mm .................................. 1
Hex Wrench 6mm .............................................. 1
Setting 90° Fence Stop
1.
DISCONNECT MACHINE FROM POWER!
2.
Loosen fence tilt lock (see Figure 25), and
press limit plate tab forward into limit block
rear slot.
Fence Carriage
Figure 25. Fence carriage overview.
3.
Use a 90° square to adjust fence to 90° (see
Figure 26), then tighten fence tilt lock.
Note: Fence should stop at 90º when it con-
tacts limit block shaft.
Machinist's
Square
Figure 26. Checking the 90º stop.
-24-
Qty
Fence
Tilt Lock
Lever
Lock Lever
— If fence does not stop at 90° when it
contacts limit block shaft, 90° stop is not
adjusted correctly. Proceed to Steps 4–6.
4.
Bring fence to 90°, then loosen jam nut locat-
ed on rear of limit block shaft (see Figure 27)
Note: Keep limit plate in limit block rear slot
while making adjustments (see Figure 27).
Inward Stop
Limit Block
Shaft
Figure 27. Fence stop parts identification.
5.
Turn limit block shaft by hand until it contacts
fence.
6.
Re-tighten jam nut. The 90° stop is now set
precisely.
Setting 45° Fence Stop
1.
DISCONNECT MACHINE FROM POWER!
2.
Use a 45° square to adjust fence to 45° posi-
tion, as shown in Figure 28.
Machinist's
Square
Figure 28. Checking 45º fence stop.
Model G0893 (Mfd. Since 03/19)
Limit Plate
Tab
Limit Block
Rear Slot
Jam Nut

Advertisement