calibrating depth
scale
the depth scale on the infeed table can be cali-
brated or "zeroed" if it is not correct.
items needed
straightedge ...................................................... 1
phillips screwdriver ........................................... 1
to calibrate the depth scale:
1.
disConneCt maChine From power!
2.
set the outfeed table height as described in
setting outfeed table height on page 24.
3.
use the straightedge to help adjust the infeed
table exactly even with the outfeed table, as
shown in figure 80.
Straightedge
Outfeed
figure 80. infeed table even with outfeed table.
4.
using a screwdriver, adjust the scale pointer
to zero (see figure 81).
depth scale
pointer
figure 81. depth scale adjusted to "0" position.
-56-
Qty
Infeed
depth scale
setting fence stops
(g0634z)
the fence stops simplify the task of adjusting the
fence to 45˚ and 90˚.
items needed
45° square ........................................................ 1
90° square ........................................................ 1
sliding Bevel ...................................................... 1
wrench 10mm ................................................... 1
to set the 90˚ fence stop:
1.
loosen the lock nut on the 90° fence stop bolt
shown in figure 82, and loosen the fence tilt
lock.
lock nut
figure 82. adjusting fence to 90˚.
2.
place a 90° square against the table and
fence, and adjust the stop bolt, so the fence
is set exactly at 90°.
3.
tighten the lock nut.
4.
adjust the indicator (if necessary) to 0° to
calibrate the fence tilt scale.
Model G0634Z/G0634XP (Mfd. Since 01/11)