Comply with the requirements of the local water supply company.
For European countries:
According to EN12729 (BA), the appliance can also be con-
nected to the mains drinking water supply if a backflow preventer
valve with drain facility is installed in the supply hose.

SPECIFICATIONS

Model:
Max. feed volume
Water flow rate
Max. permissible pressure
Working pressure
Max. feed pressure
Max. feed temperature
Max. suction height
Dimensions
(L x W x H)
Weight
Motor protection
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
Specifications may differ from country to country.
Weight according to EPTA-Procedure 01/2003
Symbols
The followings show the symbols which may be used
for the equipment. Be sure that you understand their
meaning before use.
Read the instruction manual.
Take particular care and attention.
DOUBLE INSULATION
Only for EU countries
Due to the presence of hazardous compo-
nents in the equipment, used electrical and
electronic equipment may have a negative
impact on the environment and human
health.
Do not dispose of electrical and electronic
appliances with household waste!
In accordance with the European Directive
on waste electrical and electronic equip-
ment and its adaptation to national law,
used electrical and electronic equipment
should be collected separately and
delivered to a separate collection point
for municipal waste, operating in accor-
dance with the environmental protection
regulations.
This is indicated by the symbol of the
crossed-out wheeled bin placed on the
equipment.
High mode
Low mode
HW1200
7.0 l/min
5.5 l/min
12 MPa (120 bars)
10 MPa (100 bars)
-
292 mm x 358 mm x 830 mm
11.0 kg

Intended use

This tool is intended for cleaning stubborn dirt by using
water jet. This tool is intended for household use.

Power supply

The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
10 ENGLISH
HW1300
7.5 l/min
6.0 l/min
13 MPa (130 bars)
11 MPa (110 bars)
8 MPa (80 bars)
1 MPa (10 bars)
40 °C
1.0 m
12.7 kg
IPX5
Do not direct the jet at people including
yourself, animals, and live electrical
equipments.
Not suitable for connection to the potable
water mains.
Guaranteed sound power level according
to EU Outdoor Noise Directive.
Sound power level according to Australia
NSW Noise Control Regulation