INSTALLATION MANUAL
3. Solder the center conductor to the center contact, aligning the conductor
with the slot in the contact. Avoid excess solder heat on the center BNC
conductor pin.
4. Solder the inner shield to the inside of the connector body by applying a
soldering iron to the body and running solder into the gap. Try to avoid
excess solder heat on the connector body.
5. Solder the outer shield to the outside of the connector body. Avoid excess
solder heat on the connector body. Refer to Figure 2-8.

Figure 2-8. Coax Cable Outer Shield to BNC Solder Location

6. Slide heat shrink tubing forward (flush to connector) and heat to shrink
the tubing. Refer to Figure 2-9.

Figure 2-9. Coax Cable and BNC Heat Shrink Location

7. Complete the assembly by installing the bushing over the center contact,
and fitting the cap. Solder the cap in place in at least two places. Refer to
Figure 2-10.
© Honeywell International Inc. Do not copy without express permission of Honeywell.
89000007
Page 2-17
15 Nov 2013