If a low-loss cable is needed that has too large a dielectric diameter to fit the
supplied blind-mate BNC connector, a short length (up to 6 inches (150mm))
of smaller cable may be used with suitable mating connectors to adapt to the
transponder connector.
1. Strip back the coax cable to the dimensions in table, and as shown in the
figure below. Slide 1 inch (25.4 mm) of heat shrink tubing over the cable.
Refer to Figure 2-6.
Limits
Reference
Inches (mm)
DIM. A
0.5 (12.7)
DIM. B
0.25 (6.4)
2. Insert the cable into the connector – the inner conductor should align with
the center contact, the inner shield should be inside the body of the
connector and the outer shield should be outside the body. Refer to
Figure 2-7.
Figure 2-7. Coax Cable Inner and Outer Shield Orientation
© Honeywell International Inc. Do not copy without express permission of Honeywell.
INSTALLATION MANUAL
89000007
Figure 2-6. Coax Cable Stripping Dimensions
Dimensional Limits for Figure 2-6.
Limits
Reference
Inches (mm)
DIM. C
0.125 (3.2)
Page 2-16
15 Nov 2013