Table 2-3. Maximum Usable Cable Lengths (Cont)
MAX
MAX
Length in
Length in
Feet-Inches
Meters
12-6
3.81
17-3
5.25
21-1
6.42
26-11
8.22
41-3
12.59
When routing the cable, make sure that you:
Route the cable away from sources of heat.
Route the cable away from potential interference sources such as
ignition wiring, 400 Hz generators, fluorescent lighting and electric
motors.
Allow a minimum separation of 12 inches (300 mm) from an ADF
antenna cable.
Keep the cable run as short as possible.
Avoid routing the cable around tight bends.
Avoid kinking the cable even temporarily during installation.
Secure the cable so that it cannot interfere with other systems.

2.8.2 BNC Connector

This section describes the technique for attaching the antenna cable to the
supplied blind-mate BNC connector.
© Honeywell International Inc. Do not copy without express permission of Honeywell.
INSTALLATION MANUAL
89000007
Insertion
Loss
dB/meter at
MIL-C-17
1,090 MHz
Cables
0.39
M17/112
(RG304)
0.29
M17/127
(RG393)
0.23
-
0.18
-
0.12
-
Electronic
Cable
Specialists
Type
-
311601
311501
311201
310801
Page 2-15