Pushbutton
•
To activate the detector press A.
•
To deactivate the detector, press A and hold until OFF displays (approximately 5 seconds).
•
To enable/disable the confidence beep, when the detector is deactivated press and hold C. While holding
A
C, press A. This enables/disables the confidence beep while activating the start-up process.
•
To bypass calibration after auto zero press A.
•
To access the software level information, press A at any time from any of the user options.
•
To increment a displayed value or to scroll up press G.
•
To enter the user options menu, press G and H simultaneously and hold for 5 seconds.
G
•
To clear the TWA, STEL, and MAX gas exposure readings, press C and G simultaneously.
•
To quickly scroll through options press and hold G.
•
To decrement a displayed value or scroll down press H.
•
To initiate calibration and enter alarm setpoints, press C and H simultaneously and hold for 5 seconds.
H
•
To quickly scroll through options press and hold H.
•
To view the TWA, STEL, and MAX hold readings, press C.
•
To acknowledge latched alarms press C.
C
•
To acknowledge a failed bump test screen press C.
•
At any time after auto zero, and only prior to calibration gas being detected, press C to bypass calibration
and proceed to alarm setpoints.
Table 5. Pushbuttons
Description
GasAlertMicro
Getting Started
9