Warnings For The Installer - Whirlpool AFO 642 Series Installation, Use And Maintenance Manual

Gas and electric, combined convection and direct steam injection ovens
Table of Contents

Advertisement

Available languages

Available languages

3. WARNINGS FOR THE INSTALLER

Read carefully all the instructions in this manual, because they give important suggestions about the right installation, use and
maintenance of the appliance.
3.1. CONTROLS AT RECEPTION
The appliance are shipped in appropriate protective packing. On arrival, check that the appliance has not incurred in transport
damage and that it is complete according to the order. In the event of visible damage immediately note the damage on the transport
documents with the following wording: "RECEIVED WITH RESERVE FOR EVIDENT DAMAGE OF PACKING".
ALL THE OPERATIONS INDICATED BELOW MUST BE PERFORMED IN RESPECT OF THE EXISTING SAFETY REGULATIONS,
BOTH FOR THE EQUIPMENT IN USE AND FOR THE OPERATING PROCEDURES.
3.2. HANDLING
BEFORE BEGINNING HANDLING OPERATIONS ENSURE THAT THE LIFTING CAPACITY IS ENOUGH FOR THE APPLIANCE IN
QUESTION. HANDLING with FORK LIFT or SIMILAR (A); Insert the forks into the side or back of the wooden pallet supplied with the
appliance, begin lifting checking that the appliance is in stable equilibrium. Attention: when insert the lifting device, pay attention to the
power supply cable and the position of the feet. DURING HANDLING DO NOT TIP OR TURN OVER.
the respect of the recommendations printed on the outside of the packing (D, E) is a guarantee of a sound physical and operating
condition of the appliance, all to the advantage of the end-user. therefore the following is recommended: handle with care, keep dry,
stacking of other objects on the appliance must be absolutely avoided, stacking of oven is permitted, taking care of the maximal
quantity reported on the packaging (D)
3.3. PLACING
Lift the appliance to separate it from the pallet (A). Remove the packing (B) and the protective film avoid using abrasive brushes or
other damaging materials for the appliance's surfaces (C). Check that the appliance is perfectly levelled (C).
Regulate the adjustable feet if it is necessary. If you have a composition oven + neutral element, place the oven's legs in the proper
place created in the top of the neutral element.Place the appliance away from heat sources and in a ventilated room. Never obstruct
any air inlet on the oven in order to not compromise its performance and safety when the equipment is operating .Place the
appliance in a site easy to join, so every type of maintenance, control and repair may be done easily.
A
D:GENERAL INDICATIONS ON THE PROTECTIVE PACKING
E: INDICATIONS ON THE PROTECTIVE PACKING OF THE GAS OVEN
THIS APPLIANCE MUST BE CONNECTED FOLLOWING THE NORMATIVE LAWS
IN FORCE. THIS ITEM MUST BE USED IN A VENTILATED PLACE ONLY.
GB
BEFORE THE INSTALLATION AND THE USE OF THE APPLIANCE.
INSTRUCTIONS MUST BE READ DOWN CAREFULLY. THIS PACKAGING HAS TO BE
PROPERLY RECYCLED ACCORDING TO THE EXISTING LOCAL REGULATIONS.
- It is strictly recommended to have a free space of 50 cm from the back side of the oven to the wall and from one of the two sides to
the wall in order to ensure a correct and easy connection to the equipotential system and to the electriocal and water system.
- it is recommended to have 4-6 cm of distance from the other appliances to guarantee a proper air circulation and avoid the near
surfaces to became overheated.
3.4. CONNECTIONS
3.4.1. AUTOMATIC WASHING SYSTEM
Fig. 1
B
2
1
B2
C
A2
D
18
C
Maximal quantity of stackable units
CAT
GAS PREDISPOSED
G20
20 mbar
G30
28-30 mbar
II2H3+
G31
37 mbar
Washing box (fig. 1)
Back side of the oven (see different
models in fig. 2)
Connections:
A2 + A1
B2+B1
D+D1
C in detergent tank