5.3.9.2
Network Settings
If you experience any issues, you can check the network settings using the
keypad. Proceed as follows:
Tap Menu > Installer tools > Network settings.
l
If connection is OK, it will show green tick marks with the Internet
o
connection check and MPC registration check messages.
If not, tap Enter Manual Mode to enter Manual mode. Tap Next to
o
scroll through the screens and view or edit the current network settings.
5.3.9.3
Factory Default
You can use the factory default function on the keypad to delete the control
panel configuration and reset all values to the factory settings. This will also
delete all keypad users, except the default Installer and Master user.
If you want to remove a control panel from an installation, or decommission it,
you must execute this function on the keypad before you delete the control
panel from MAXPRO Cloud. For details, see Decommissioning a Control Panel
after Resetting to Defaults on page 67.
You can also use factory defaulting to try and resolve issues with the control
panel, for example if the configuration is corrupted. In this case, you can reset
the control panel configuration to default values using the keypad, and then
use MAXPRO Cloud to restore the control panel's configuration. For details, see
Restoring the Panel's Configuration after Resetting to Defaults on page 68.
To reset the control panel to factory defaults, proceed as follows:
1.
Tap Menu > Factory default.
A warning appears on the keypad screen.
2.
Proceed as follows:
Tap Continue to confirm.
o
Tap Back to cancel.
o
The system resets the control panel's settings and restarts the panel.
5.3.9.4
Decommissioning a Control Panel after Resetting to Defaults
Before decommissioning or uninstalling a control panel, make sure to execute
the factory default function on the keypad to clear all data in the control panel
before removing it.