PROMPTS
Telco Zone
31
(0)_
Open/Close Zone
32
(0)_
Zn1 Trigger Type
33
(V+)_
Restore Zn1 Y/N
34
(Y)_
Delay Zn1 (secs)
35
(00)_
Rpt Zn1 ONLY if
36
Armed (N)_
Invert Zn2 Y/N
37
(N)_
Restore Zn2 Y/N
38
(Y)_
Programming for Zone Trigger, 4204 and Two-4204 Modes
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
See Important Information Regarding Zone
Zone Trig: [3-
Input Options on previous page.
7]
Enter the zone number to be used for telco line
4204: [1-4]
fault reports. This zone assignment must be
unique from the open/close zone selected in
2-4204: [1-8]
Prompt 32.
[0] = not
Zone Trigger Mode: If any zone is programmed
used
for "report only if armed," zone 7 cannot be used.
If LYNX Panic is enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be used.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used.
NOTE: Connect the Telco line fault output (or
relay output programmed for "Telco line fault")
to the Telco zone.
Enter the zone number to be used for open/close
Zone Trig: [3-
(arm/disarm) reports.
7]
This zone assignment must be unique from the
4204: [1-4]
Telco zone selected in Prompt 31.
Zone Trigger Mode: If any zone is programmed
2-4204: [1-8]
for "report only if armed," zone 7 cannot be used
[0] = not
as an open/close zone. If LYNX Panic is enabled,
used
zone 3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be used as
an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [Space] key to scroll through choices.
• (V–)
[Y], [N]
Enables restore reporting for zone 1.
[01-15]
Defines the reporting delay in seconds for zone 1.
[00] = no
delay
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
[Y], [N]
Inverts the alarm and normal states of the zone
2 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 2.