Honeywell AlarmNet GSMBR Installation And Setup Manual page 31

Communications module
Table of Contents

Advertisement

PROMPTS
Prompt 22 appears for the iGSMBR only.
IP Flt Time
22
(00 mins)_
GSM Flt Time
23
(00 mins)_
Prompt 24 appears for the iGSMBR only.
Notify Panel Of_
24
(Neither Fault)_
Flt Rel ON Y/N
25
(N)_
Pwr Loss Rpt Y/N
26
(Y)_
Low Bat Rpt Y/N
27
(Y)_
Tamper Rpt Y/N
28
(Y)_
Programming for Zone Trigger, 4204 and Two-4204 Modes
4204/
ZONE
ENTRY
2-4204
TRIG.
OPTIONS
[00-99]
In the event there is a loss of contact with the
network over the Ethernet connection, enter the
time delay (in minutes) before the
tions module
failure will always be sent to the central station
as Primary Communication Path Failure.
[00-99]
In the event the module detects a communication
path failure, enter the time delay (in minutes)
before the
central station. For an iGSMBR, a GSM failure
will always be sent to the central station as
Secondary Communication Path Failure. For a
GSMBR, a GSM failure will be sent to the
central station as a Primary Communication
Path Failure.
If "Both IP and GSM Fault" is selected, the
[Neither
device will only notify the control panel if both
fault]
communication paths fail, but will always send
notification of either failure to the central
[Both IP
station.
and GSM
Faults]
NOTE: The fault relay output (if programmed)
will be triggered only if "Both IP and GSM
Faults" is selected.
Press the [Space] key to scroll through choices.
If enabled, the fault open collector output is
[Y], [N]
normally energized to ground, and de-energizes
(open circuit) in the event of a module fault. For
conditions that trip the fault relay refer to
Module Supervision Features in Section 1.
Set to [Y] if fail-safe mode is desired.
See Wiring for Module Fault Relay in Section 2.
Sends a primary power loss report to the central
[Y], [N]
station within 1-3 hours after its detection. A
restore report is sent within 1-3 hours after
power is restored.
Suggested Setting: When using a transformer
and battery, set to "Y".
When using a LYNXR-I series control set to "N".
[Y], [N]
Sends a low battery report when a low battery
condition exists. A low battery restore is sent
when the condition clears.
Suggested Setting: When using a transformer
and battery, set to "Y".
When using a LYNXR-I series control set to "N".
[Y], [N]
Sends a tamper report when the module detects
a tamper condition. A tamper restore is
automatically sent when the tamper condition
clears.
Section 3: Programming
DESCRIPTION
communica-
notifies the central station. IP
communications module
notifies the
3-15