Honeywell Velociti AOM-2RF Installation And Maintenance Instructions

Honeywell Velociti AOM-2RF Installation And Maintenance Instructions

Relay control module

Advertisement

Quick Links

INSTALLATION AND MAINTENANCE INSTRUCTIONS
Velociti
Series
®
AOM-2RF Relay Control Module
SPECIFICATIONS
Normal Operating Voltage:
Maximum Current Draw:
Average Operating Current:
EOL Resistance:
Temperature Range:
Humidity:
Dimensions:
Accessories:
RELAY CONTACT RATINGS:
CURRENT RATING
2 A
3 A
2 A
0.46 A
0.7 A
0.9 A
0.5 A
0.3 A
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer to
the appropriate Gamewell-FCI control panel installation manual for detailed
system information. If the modules will be installed in an existing operational
system, inform the operator and local authority that the system will be tem-
porarily out of service. Disconnect power to the control panel before installing
the modules.
NOTICE: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
The AOM-2RF Relay Control Module is intended for use in intelligent, two-
wire systems where the individual address of each module is selected using
the built-in rotary switches. It allows a compatible control panel to switch
discrete contacts by code command. The relay contains two isolated sets of
Form-C contacts, which operate as a DPDT switch and are rated in accordance
with the table in the manual. Circuit connections to the relay contacts are
not supervised by the module. The module also has a panel controlled LED
indicator. This module can be used to replace a AOM-2 module that has been
configured for Form-C operation.
COMPATIBILITY REQUIREMENTS
To ensure proper operation, this module shall be connected to a compatible
Gamewell-FCI system control panel (list available from Gamewell-FCI).
15 to 32 VDC
6.5 mA (LED on)
230µA (LED flashing) Velociti Mode; 255µA (LED flashing) CLIP Mode
Not used
32˚F to 120˚F (0˚C to 49˚C)
10% to 93% Non-condensing
4.675" H x 4.275" W x 1.4" D (Mounts to a 4˝ square by 2
SMB500 Electrical Box; CB500 Barrier
MAXIMUM VOLTAGE
25 VAC
30 VDC
30 VDC
30 VDC
70.7 VAC
125 VDC
125 VAC
125 VAC
1
/
˝ deep box.)
8
LOAD DESCRIPTION
PF = 0.35
RESISTIVE
RESISTIVE
(L/R = 20MS)
PF = 0.35
RESISTIVE
PF = 0.75
PF = 0.35
FIGURE 1. CONTROLS AND INDICATORS:
1
12 Clintonville Road
Northford, CT 06472-1653
Phone: 203.484.7161; Fax: 203.484.7118
www.gamewell-fci.com
APPLICATION
NON-CODED
NON-CODED
CODED
NON-CODED
NON-CODED
NON-CODED
NON-CODED
NON-CODED
C1071-00
I56-3551-006
02-14

Advertisement

loading

Summary of Contents for Honeywell Velociti AOM-2RF

  • Page 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS Velociti Series ® 12 Clintonville Road Northford, CT 06472-1653 AOM-2RF Relay Control Module Phone: 203.484.7161; Fax: 203.484.7118 www.gamewell-fci.com SPECIFICATIONS Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 6.5 mA (LED on) Average Operating Current: 230µA (LED flashing) Velociti Mode;...