Description 
19 
Take the compensating plate. Replace the 
O‐ring (2) with a new, greased O‐ring. 
Check the sliding ring (1) for damage. 
Replace it if necessary. 
20 
Slide the compensating plate onto the 
valve shank all the way to the stop. Im‐
portant! Make sure not to damage the 
O‐ring (1) or change its position. Make sure 
that the compensating plate is positioned 
correctly. The sliding ring (2) should be on 
top and the O‐ring (3) underneath it. 
21 
Secure the compensating plate with a new 
retaining ring (1). 
22 
Insert the valve shank (1) back into the 
actuator assembly from above. The 
compensating plate should sit tightly inside 
the upper part of the guide bush (2). 
23 
Take the valve plate. Check the sealing 
edge for damage. The sealing edge must 
not have any scratches or dents. If neces‐
sary, replace the valve plate with a new 
one. 
 