Honeywell HON R100NG Series User And Maintenance Manual page 54

Gas pressure regulator with pilot
Table of Contents

Advertisement

User manual for HON R100 gas pressure regulator with HON P095NG pilot 
Figure 
Step 
Description 
Unscrew the valve plate's locknut (1) from 
below. While doing so, secure the valve 
shank from above. 
From below, remove the support cage (1) 
and the valve plate (2). To do so, use the 
holes in the support cage (3). Important! 
Both components feature sealing edges 
that must not be damaged! 
10 
Pull out the valve shank, including the 
compensating plate, upward. 
11 
Hold the guide bush (2) in place from 
below. Unscrew the hold screw (1). Re‐
move the guide bush. Use a rubber mallet 
if necessary. Important! Make sure not to 
damage the guide bush – especially the 
sealing edges. 
12 
Check the guide bush's sealing face for 
damage. The sealing face must not have 
any scratches or dents. If necessary, 
replace the guide bush with a new one. 
 