You can configure applicator port settings from the web browser interface or in
Setup Mode.

Web Browser Interface

1.
From the menu, click System Settings > Manage I/O. The configuration
screen appears.
2.
Chose Enable from the drop down list for the Applicator.
3.
From the menu, click Configure > Printing > Applicator.
4.
Choose desired settings from the drop down lists.
Setting
Style
Startprint
Endprint
Ribbon/Media Low
Reprint
Error on Pause
Error Port
RTW
DC 5V
PX940 Applicator Interface Installation Instructions
Description
I-Style, Z-Style, S-Style
Level or Pulse
Mode 0, Mode 1/Type3, Mode2/Type4, Mode3/Type 1,
Mode 4/Type 2
Enables/disables the printer low ribbon alert message.
Enables/disables the printer low media alert message.
Enables/disables reprinting the last label sent to the
printer (by using the Reprint signal)
Enable this setting to set the "Service Required" signal
when the printer is paused. This setting supported by
Z-Style only.
Enables/disables the printer external error port.
Configures the Ready-to-Work output signal
(RTWOUTEXT). Choose from:
• Mode 1 - Signal is asserted low when no events are
active in the System Health Monitor (SHM).
• Mode 2 - Signal is asserted low when the printer motor
is idle.
• Mode 3 - Signal is asserted low when the printer motor
is idle and no events are active in the SHM.
Configures the printer to use either its internal power
supply or an external supply (connected to the External
Power port) to provide +5VDC to the Z-Style and S-Style
ports.