Setup Mode - Honeywell PX940 Installation Instruction

Applicator interface board
Hide thumbs Also See for PX940:
Table of Contents

Advertisement

Setting
DC 24V
5.
Click Save. The settings are saved.

Setup Mode

Use the printer touch screen to view and change settings.
1.
Press Menu > Settings > System Settings > Manage I/O.
2.
Choose Enable from the drop-down list for the applicator.
3.
From the menu, select Menu > Settings > Printing > Applicator.
About Applicator Input Signals
This section describes the INPUT signals.
Note: All IN signals are asserted low and de-asserted high.
Signal
Startprint
Feed
Pause
Reprint
Apperr1
Apperr2
Apperr3
RTWINEXT
16
Description
Configures the printer to use either its internal power
supply or an external supply (connected to the External
Power port) to provide +24VDC to the Z-Style and
S-Style ports.
Description
Starts a print job. Choose either Level or Pulse.
• Level: The printer starts printing labels when the
startprint signal is asserted and continues printing
until the signal is de-asserted.
• Pulse: The printer prints one label when the startprint
signal is asserted. The startprint signal must be
de-asserted and then asserted to print the next label.
Feeds a single label. Not supported by S-Style.
Toggles between Pause mode and printing. Not
supported by S-Style.
Reprints the last valid label.
Applicator error 1.
Applicator error 2.
Applicator error 3.
External input signal, which you can use to monitor the
operational status of the entire system.