External Error Port Pinouts
Pin
Signal
1
AppErr_1
2
AppErr_2
3
AppErr_3
4
RtW_in_Ext
5
+5VDC
6
RtW_Out
7
Ground
8
Ground
Applicator Signals
The diagrams below show how applicator signals function in each applicator
mode during the stages of printing labels.
12
Type
Description
Applicator error #1,
Input
applicator device to signal error for
printer to receive status of applicator.
Applicator error #2,
Input
applicator device to signal error for
printer to receive status of applicator.
Applicator error #3,
Input
applicator device to signal error for
printer to receive status of applicator.
External input signal from the applicator to
Input
the printer, for the printer to switch to the
same state with the applicator, and behave in
sync as part of the entire system.
Available for applicator.
Output
External output signal indicating the printer
Output
is Ready to Work.
Signal may be asserted LOW when there are
no active events in the System Health
Monitor (SHM), when the printer motor is
idle, or both.
Available for applicator.
Ground
Available for applicator.
Ground
PX940 Applicator Interface Installation Instructions