Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
Figure 15: Fan -Tray Extracted Partially with Power Connector Disconnected
Step 3
When the fans have stopped, pull the fan-tray assembly completely out of the shelf assembly (see the following
figure).
Figure 16: Fan-Tray Extracted
Step 4
Slide the new fan-tray assembly into the shelf assembly until the electrical plug at the rear of the tray plugs
into the corresponding receptacle on the backplane.
Step 5
To verify that the tray has plugged into the backplane, ensure that the LCD on the front of the fan-tray is
activated.
Stop. You have completed this procedure.