Magnesium Frame - Honeywell CK75 Repair Manual

Hide thumbs Also See for CK75:
Table of Contents

Advertisement

TITLE
CK75 Repair Manual
3.
Remove the scan bracket assembly (refer to scan bracket assembly operation).
4.
Remove the display assembly (refer to LCD Display & Touch Panel operation).
5.
Using a T7 torx driver remove three screws that attach the main logic board to the magnesium frame.
Installation
1.
Position the main logic board onto the magnesium frame.
2.
Using a T7 torx driver install 4 screws and secure the main logic board to the magnesium frame with 2.5+/-0.2 inlbs of
torque.
3.
Re-install the display assembly.
4.
Re-install the Scan bracket assembly.
5.
Re-install the core assembly into the top housing.
6.
Re-install the bottom housing assembly.
OPERATION:

Magnesium Frame

Replacement of the magnesium frame will require a complete disassembly of the unit.
Tools Required
Description
T10 Torx driver
T7 Torx driver
Phillips screwdriver with #0 tip
Model
DOCUMENT NO.
L3-GLBL-RPR-4254
CK75
(Rev A)
L3-GLBL-RPR-4516 (Rev A)
PAGE
Page 38 of 42
Part Number

Hide quick links: