Honeywell AlarmNet IGSMHS Installation And Setup Manual page 48

Internet communication module
Table of Contents

Advertisement

IGSMHS Installation and Setup Guide
Bat NLd: x.xxV
Bat Ld:
Battery Charger
OK
Line Voltage
xx.xxV
[T]
Test Msg Sent
[X]
Reset CPU Y/N
[]
Registering ...
(UP
arrow)
[]
Enter PIN#
(DN
arrow)
[0]
Force Server Update?
Y/N
[ENT
Strt Prog Mode?
ER]
Y/N_
5-4
Battery Voltage Display
The voltage levels of the battery connected to the
x.xxV
IGSMHS can be viewed on the 7720P. The first line of the display shows
the voltage level of the battery with no load. The second line of the
display shows loaded battery voltage. An asterisk (*) next to the voltage
indicates that this is below the accepted level.
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Battery Charger Status Display
The status of the battery charger circuit of the
IGSMHS can be viewed on the 7720P. The status is either OK or NOT
OK.
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Line Voltage Display
The line voltage of the IGSMHS can be viewed on the 7720P. An asterisk
(*) next to the voltage indicates that this is below the accepted level.
Press the [Space] key to go back to the System Status Display.
Press the backspace [BS] key to go to the previous field.
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a registered IGSMHS
only. If the device is not registered, a message is displayed indicating
that the command cannot be executed.
Reset the IGSMHS.
Pressing [N] returns to diagnostic mode (blank screen = enter next
command or escape).
Pressing [Y] resets the module (blank screen = reset complete).
Registration
Registers a programmed IGSMHS with AlarmNet.
Registration with PIN for Replacement Module
Registers a replacement IGSMHS with AlarmNet, once programmed,
using the existing PIN #.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configuration file to
the server.
Pressing [N] cancels the operation.
NOTE: If the internet is not available, and the IGSMHS module is not
initialized when you enter this command, the following screen will be
displayed:
Cannot Upload
Try Later! _
Wait for the RSSI LEDs to light, indicating the IGSMHS module has
completed its initialization, and try again.
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].

Advertisement

Table of Contents
loading

Table of Contents