IGSMHS Installation and Setup Guide
PROMPTS
Zn5 Trigger Type
49
(V+)_
Invert Zn5 Y/N
50
(N)_
Restore Zn5 Y/N
51
(Y)_
Delay Zn5 (secs)
52
(00)_
Rpt Zn5 ONLY if
53
Armed (N)_
Enable Zn6 Y/N
54
(N)_
Zn6 Trigger Type
55
(V+)_
Invert Zn6 Y/N
56
(N)_
Restore Zn6 Y/N
57
(Y)_
Delay Zn6 (secs)
58
(00)_
Rpt Zn6 ONLY if
59
Armed (N)_
60
Enable Zn7 Y/N
(N)_
Zn7 Trigger Type
61
(V+)_
62
Invert Zn7 Y/N
(N)_
3-18
4204/
ZONE
ENTRY
TRIG.
2-4204
2-
4204
only
2-
4204
only
2-
4204
only
4204
only
4204
only
4204
only
4204
only
4204
only
4204
only
OPTIONS
 (EOLR)
Selects the triggering method for this zone
 (V+)
input. Press the [space] key to scroll through
choices.
 (V–)
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the zone
5 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 5.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 5.
[00] = no
UL: Must be set to 00.
delay
[Y], [N]
Reports alarms on zone 5 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
Enables alarm reporting for zone 6.
[Y], [N]
If [N], skip to Prompt 60: "Enable Zn7."
 (EOLR)
Selects the triggering method for this zone
 (V+)
input. Press the [space] key to scroll through
choices.
 (V–)
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the zone
6 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 6.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 6.
[00] = no
UL: Must be set to 00.
delay
[Y], [N]
Reports alarms on zone 6 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 6.
[Y], [N]
Enables alarm reporting for zone 7.
If [N], skip to Prompt 68: "Use DHCP."
 (EOLR)
Selects the triggering method for this zone
 (V+)
input. Press the [space] key to scroll through
 (V–)
choices.
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the zone
7 trigger; otherwise uses normal input signal.
DESCRIPTION