IGSMHS Installation and Setup Guide
PROMPTS
Telco Zone
29
(0)_
Open/Close Zone
30
(0)_
Zn1 Trigger Type
31
(V+)_
Restore Zn1 Y/N
32
(Y)_
Delay Zn1 (secs)
33
(00)_
Rpt Zn1 ONLY if
34
Armed (N)_
Invert Zn2 Y/N
35
(N)_
3-16
4204/
ZONE
ENTRY
TRIG.
2-4204
OPTIONS
See Important Information above, Regarding
Zone Trig:
Zone Input Options.
[3-7]
Enter the zone number to be used for Telco line
4204: [1-4]
fault reports. This zone assignment must be
unique from the open/close zone selected in
2-4204:
Prompt 30.
[1-8]
Zone Trigger Mode: If any zone is
[0] = not
programmed for "report only if armed," zone
used
7 cannot be used. If Lynx Panic is enabled,
zone 3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be
used.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used.
NOTE: Connect the Telco line fault output (or
relay output programmed for "Telco line fault")
to the Telco zone.
Enter the zone number to be used for open/close
Zone Trig:
(arm/disarm) reports.
[3-7]
This zone assignment must be unique from the
4204: [1-4]
Telco zone selected in Prompt 29.
2-4204:
Zone Trigger Mode: If any zone is
[1-8]
programmed for "report only if armed," zone
7 cannot be used as an open/close zone. If
[0] = not
Lynx Panic is enabled, zone 3 cannot be
used
used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be used
as an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used as an
open/close zone.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel
to the open/close zone.
 (EOLR)
Selects the triggering method for this zone
 (V+)
input. Press the [space] key to scroll through
 (V–)
choices.
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Enables restore reporting for zone 1.
UL: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 1.
[00] = no
UL: Must be set to 00.
delay
[Y], [N]
Report alarms on zone 1 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; or zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 1.
[Y], [N]
Inverts the alarm and normal states of the zone
2 trigger; otherwise uses normal input signal.
DESCRIPTION