Configure The Blade Chassis - Cisco RP Series Installation Manual

Rack and metered input pdu
Hide thumbs Also See for RP Series:
Table of Contents

Advertisement

Integrating UCS Components in the Dynamic Rack

Configure the Blade Chassis

To configure the blade chassis, follow these steps:
Procedure
Step 1
Launch a web browser and enter the cluster IP address in the URL address field.
Step 2
Click Launch UCS Manager.
Step 3
Log into UCS Manager using the following paramenters:
a) User ID: admin
b) Password: Disti100
Step 4
Configure the Equipment Policies.
a) In the Navigation Pane, select the Equipment tab.
b) Click the Equipment node and select the Policies tab in the Work Pane.
Chassis/FEX Discovery Policy
Rack Server Discovery Policy
Rack Management Connection Policy
Power Policy
Mac Address Table Aging
Global Power Allocation Policy
Firmware Auto Sync Server Policy
• On the Action list, select the number of physical links (server port links) to be used by the chassis
under the section. This number is the number of links of Twinax connections used under the Cabling
section.
• Under Link Grouping Preference, select None.
• Select Immediate.
• Scrub Policy <not set>.
• In the Action list, select Auto Acknowledged.
• In the Redundancy list, select the following for the UCS 5108 Blade Server chassis:
For two power supplies, select Non-Redundant.
For three power supplies, select N+1.
For four power supplies, select Grid.
• On the Aging Time list, leave the setting as Default Mode.
• On the Allocation Method list, leave the setting as Policy Driven Chassis Group Cap.
• On the Sync State list, select Auto Acknowledge.
Cisco R42612 Rack and RP-Series Metered Input PDU Installation Guide
Configure the Blade Chassis
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

R42612 r seriesRack2-ucsRack2-ucs2Rack2-ucs2-int

Table of Contents