5.2.2 Magnetic Pickup

Table 5-3 shows the signals coming out of the Acquisition Unit for each magnetic pickup
connector on the Unit. Figure 5-3 shows the magnetic pickup cable wiring schematic.
Table 5-3. Acquisition Unit Magnetic Pickup Connector Pinouts
Pin #
Function
A
Sensor Power
B
Mag Pickup/Photocell Signal #
C
Spare
D
Ground
NOTE: The Magnetic Pickup input is also compatible with the external Chadwick-
Helmuth photocell processor.
Figure 5-3. Wiring Schematic, Magnetic Pickup Cable P/N 902-10808
5-4
Honeywell
Attributes
+12 Vdc
0.2 to 10 Vac
N/A
Ground