Honeywell VXP System Maintenance Manual page 35

Vibration analysis system
Table of Contents

Advertisement

Table 2-2. Preparation and Checkout Procedure (Continued)
Item
DP Software
AU Software
System BIT Check
Checklist Completion
Check For
Turn on the DU, and wait for the main desktop to appear.
Launch the VXP DP by touching the VXP icon on the desktop
twice in rapid succession, and verify that the DP starts. Once the
DP starts, continue with the remaining checks. If the VXP icon
is not present or the DP fails to start, refer to section 2.2.2.1 for
software loading instructions.
In the start-up menu of the DP, establish communication with
the AU by touching the OK button or pressing the Enter key
(the "Connect To AU" option is selected by default), and verify
that the AP main menu appears. If the AU and DU are
communicating properly, the application program main menu
will be displayed.
Print the fault log as follows:
1. Press the Print icon on the left side of the display.
2. Press the Fault Log button in the Print menu.
Verify that there are no faults in the log. If a printer is not
attached to the system, the Fault Log may be viewed as follows:
3. Click the View Log menu.
4. Select System Faults and press the View
button. The Message from View Log should read
"There are no common faults."
5. Press the Detail button to view the fault log.
Verify that there are no errors in the Fault Log. Refer to Section
4.4 for detailed error message descriptions.
Exit the DP as follows: Touch the Exit icon on the left side of
the display. Choose an exit option.
Preparation for Use
VXP System Maintenance Manual
2-7

Hide quick links:

Advertisement

Table of Contents
loading