Introduction
Table 1-3. Acquisition Unit Leading Particulars (Continued)
Parameter
Interfaces
Balance
Amplitude Accuracy
Phase Resolution
Frequency Range
Harmonics
Simultaneous Channels
Vector Operations
Spectrum
Frequency Ranges
Frequency Resolution
Window Types
Simultaneous Channels
Dynamic Range
Averaging
Amplitude Accuracy
1-10 Honeywell
Characteristic
Magnetic Pickup/Photocell: 4
Photoprobe, High Speed: 2
Velocimeter: 16
Accelerometer (ICP): 26
Accelerometer (HTA): 6
Discrete Signal I/O: 6
Strobex: 1
Fastrak: 2
PCMCIA Type 2 Card Slot (on-board
configuration): 1
USB: 1
High Speed Tach: 4
±2%
1 degree
180 to 60,000 rpm
1 to 5
4 vibration
1 azimuth
1 FasTrak
(A + B)/2, (A - B)/2
0 - 20 Hz to 0 - 75 KHz
400 to 51,200 lines
Flat-top, Hanning, Kaiser-Bessel, Uniform
4 vibration
1 azimuth
> 90 dB
Linear, Peak hold
±2%