Function and System Design

2.1

Overview

2.1.1

ProcessMaster

Integral mount design
FEP611
1
Fig. 1:
Designs
1 Flowmeter sensor, Design Level A (DN 3 ... 2000) 2 Flowmeter sensor, Design Level B (DN 25 ... 600) 3 Remote transmitter
Flowmeter sensor
Model
Housing
Measuring accuracy for liquids
Permissible measuring medium
temperature T
medium
Minimum conductivity
Nominal pressure rating
Nominal diameter
Process connection
Process connection material
Liner material
Electrode material
IP rating
Approvals
Pressure Equipment Directive
2014/68/EU
CRN (Canadian Reg.Number)
Further approvals
1) For information on flange thicknesses, see the chapter "Dimensions" in the Datasheet.
6 OI/FEP610/FEH610-EN Rev. B | ProcessMaster FEP610, HygienicMaster FEH610
FEP611
2
ProcessMaster FEP611, FEP612
Integral mount design, remote mount design
0.5 % of measured value
-25 ... 130 °C (-13 ... 266 °F)
> 20 μS/cm (20 μS/cm for demineralized water)
PN 10 ... 40; ASME CL 150, 300; JIS 10K
DN 3 ... 2000 (1/10 " ... 80 ")
1)
Flange
according to DIN, ASME, JIS
Steel, cast iron, stainless steel
Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600), PFA (DN 3 ... 200),
ETFE (DN 25 ... 600)
Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium
Integral mount design: IP 65 / IP 67
Remote mount design: IP 65 / IP 67 / IP 68 (sensor only)
Conformity assessment in accordance with category III, fluid group 1
On request
At www.abb.com/flow or on request.
Remote mount design
FEP612
FEP612
1
2
FET612
3
G12001