Location; Connections - Honeywell Enraf SmartRadar FlexLine Installation Manual

Table of Contents

Advertisement

Installation

4.11.2.1 Location

The terminal compartment is located at the rear, inside of the
device (see FIG. 4-7). If there is a SmartConn present, you use
the terminals of the SmartConn (see FIG. 4-6). These terminals
are numbered identical to the terminal compartment in the
device.

4.11.2.2 Connections

The intrinsically safe cabling must enter at the gland (C) only.
This entry is marked "Ex-i". See FIG. 4-6. Blue marked cables
are recommended for the intrinsically safe options.
C
FIG. 4-6 Ex-i entry with SmartConn
A
B
C
Installation Guide
30
A
Description
Blue terminals, for intrinsically safe connections
Grey terminals, for non-intrinsically safe connections
Glands for intrinsically safe cabling only
SmartRadar FlexLine
B
Part No.: 4417.760_Rev06

Advertisement

Table of Contents
loading

Table of Contents