Touch Panel Test - Casio QT-7300 Service Manual

Electronic cash register
Hide thumbs Also See for QT-7300:
Table of Contents

Advertisement

6-4. Touch panel test

Set the driver then activate the calibration software.
The following shows the software list and the test procedures.
Software Files
1) For DOS
* medv10.com
* caldos.com
2) For Windows95
* fidmour.drv
* vfidmd.386
* fidmour.inf
* calwinr.exe
3) For WindowsNT
* fidtpntr.sys
* fidtpntr.inf
* calwinre.exe
4) Inxxxxxxl.doc
Copy necessary files into the Floppy Disk based on you target Operation System.
Setup procedure
1) For DOS
1 Copy the Driver software into the proper directory.
2 Execute the "medv10.com".
2) For
Windows95
1 Open "Control Panel" <Click "Start", select "Setting" then select "Control Panel">
2 Double Click "Add New Hardware"
3 In "Add New Hardware Wizard", Click "Next"
4 Select "No" at Hardware Automatic Detection then Click "Next"
5 Select "Mouse" at Hardware setup then Click "Next"
6 Click "Hard Disk" at Manufacture and Model selection
7 Insert Floppy Disk(Driver copied) into Drive ("A:") then Click "OK"
8 "Fujitsu Fidmouse" will be displayed then Click "OK"
9 END (Restart the system )
3) For WindowsNT
1 Open "Control Panel"
2 Select "Mouse"
3 Insert Floppy Disk(Driver copied) into Drive("A")
4 Open "property" sheet in "General" then click "Use Disk"
5 Select "Fujitsu Takamisawa component Fidmouse" Then "OK"
*** START INSTALLATION ***
6 END ( Restart the system )
Device Driver
Calibration program
Device Driver
Device Driver
Device Driver information file
Calibration program
Device Driver
Device Driver information file
Calibration program
This file ( xxxxxx = YYMMDD)