Removing The Front Panel Module - Fujitsu PRIMERGY RX2560 M2 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2560 M2:
Table of Contents

Advertisement

"Removing the system air duct" on page 91
Ê
"Removing the system fan holder" on page 93
Ê

13.1.2 Removing the front panel module

Removing front panel cables from the system board
Figure 322: Disconnecting the front panel cables
Ê Disconnect the front panel cable from the system board (1).
Ê If applicable, disconnect the front VGA cable from the system board (2).
Ê Disconnect the front USB cable from the system board (3).
Ê Remove all front panel cables from the cable guide (A).
Removing the front panel module
I
Unlocking and securing the front panel is illustrated by the example of the
rack server. In case of tower servers, the accessible drive locking bar is
located on the top of the drive bay. Further information see section
"Opening the accessible drive locking bar" on page
TX2560 M2 / RX2560 M2
Front panel and external connectors
Upgrade and Maintenance Manual