Wiring Guides - Honeywell Prestige THX9321 System Installation Manual

Hide thumbs Also See for Prestige THX9321:
Table of Contents

Advertisement

THX9321/9421
Prestige
_ IAQ and RF ElM
Thermostat
wiring
guides
-- Prestige
THX9321
Typical
wiring
of a 3-heat
/ 2-coot
heat
pump
system
with
one transformer
Transformer
_D
R24
C
®U2
MCR32948
Typical wiring of a 3-heat / 2-cool heat
pump system with two transformers
®R
© u2
OR ZONE PANEL
_} U2
Backup
Beat
_
R
............
i..............................
Transformer
_
C
MCR32950
Typical
wiring
of a 2-heat
/ 2-cool
con-
ventional
system
with
one transformer
Transformer
_A4CR24
C
'
©Re
oR
_
®W
Qw
®U2
MCR32949
Typical
wiring
for geothermal
radiant
heat,
geothermal
forced-air
and back-
up heat
with
one transformer
Transf
..... __
I©c
i©mo
o_
I®R
i
EOTHERMAL
IQ U1
- :2-
i
HEAT
i@U
=_"
UA
STAGE I
'(_ U 2 T _
MCR32951
U1 and U2 terminals are dry contacts.
A
L/A terminal sends continuousoutputwhen thermostat is set to EM HEAT modeexceptwhen set up for Economizeror TOD.
See Economizerwiring section,
A
U1 or U2terminals mustbe used for geothermal radiant heat (ISU2010). Thermostatallows 2 stages of radiant heat--
geothermal(stage 1) and boiler (stage2),
_I_
"U"terminals are normallyopen dry contactswhen set up for geothermal radiant heat.Youmust install a field jumper if radiant
heat is powered by system transformer.Do NOTinstall a field jumper if radiant heat has its own transformer.
A
Removejumper if using separate transformers,
Connectthe THP9045Wiresaver Moduleto the K terminal in heating/cooling applicationsthat do not havea common wire
at the thermostat,The K terminal cannot be used in heat-onlyapplications.See THP9045 installationinstructionsfor more
information.
13
69-2490--03