Honeywell Prestige THX9321 System Installation Manual page 22

Hide thumbs Also See for Prestige THX9321:
Table of Contents

Advertisement

System Installation
Guide
Commercial
dehumidification
Dehumidification
Equipment
Options:
(iSU 9000)
A/C with
Low Speed
Fan
A/C with
High Speed
Fan
Hot Gas Bypass
Dehumidifier
When
set for A/C
with Low
Speed
Fan, A/C with
High
Speed
Fan or Hot Gas
Bypass,
there
are five methods
of dehumidification
control:
(iSU 9080) See
descriptions
of each,
below.
1
Minimum
On Time
2
High
Humidity
Comfort
Reset
3
High
Humidity
Comfort
Reset
with
Minimum
On Time
4
Reheat
5
Reheat
with
Minimum
On Time
f
Minimum
On Time
(ISU 9090): This option
ensures
that the compressor
runs
tong
enough
to effectively
reduce
humidity
when
the cooling
equipment
is cycled
on. The compressor
will run for the minimum
"on time"
you set untit the desired
humidity
level is reached.
2
High
Humidity
Comfort
Reset
(ISU 9100):
This option
uses the cooling
system
to lower the temperature
up to 5 ° F below
the current
cool
setpoint
until the desired
humidity
is reached.
The high
humidity
comfort
range
is
froml°to5
°R
3
High
Humidity
Comfort
Reset
with
Minimum
On Time
(ISU 9090
and
9100): This
method
uses both
options
above
to reduce
humidity
while
maintaining
a comfortable
temperature.
4
Reheat
(ISU 9080): This option
allows
heating
to run during
dehumidification
to help
maintain
a comfortable
temperature,
if only
cooling
stage
1 is used,
during
the "off"
cycle,
both
cooling
and heating
run at the
same
time
as needed
to dehumidify
without
overcooling.
This option
cannot
be used
in the Heat mode.
This option
is effective
only
if using
a system
with
the A=Ooil
located
before
the plenum.
5
Reheat
with
Minimum
On Time
(ISU 9080
and 9090)
This method
uses both
Reheat
and Minimum
On Time
options
above
to
reach
the desired
humidity
level.
The Dehumidifier
option
requires
a dedicated
unit for dehumidification.
The ther-
mostat
can
be set to control
dehumidification
in all modes
(Heat,
Off, Cool
[ISU
9120]).
Hot Gas Bypass- Duringa call for dehumidification,the cooling capacitywill be used to removemore latentheat
than sensibleheat. The operation of Hot Gas Bypassvaries by equipment.Far more details,contact the equipment
manufacturer.
To see all dehumidificationoptions,press MENU> INSTALLEROPTIONS> VIEW/EDITCURRENT SETUP>
DEHUMIDIFICATION.
69-2490--03
22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prestige thx9421

Table of Contents