Honeywell Prestige THX9321 System Installation Manual page 20

Hide thumbs Also See for Prestige THX9321:
Table of Contents

Advertisement

System Installation
Guide
Basic
and Advanced
Temperature
Control
Options
{iSU 3010)
Basic
Options:
The Installer
Setup
displays
basic
temperature
control
options
which
include
Backup
Heat Differential,
Backup
Heat
Upstage
Timer
and Outdoor
Temperature
Lockouts.
Note:
Outdoor
Temperature
Lockouts
only apply
to Heat
Pump
applications.
Advanced
Options:
The Installer
Setup
displays
both
Basic
and Advanced
Options.
Advanced
temperature
control
options
include
Finish With
High Coot
Stage,
Finish
With
High
Heat Stage,
Temperature
Differential
settings
per stage
and Cycle
Rate settings
per stage.
FinishWith High Heat or C001 Stage- Whena multi-stage heatingor coolingsystem is used,this featurekeeps the high stage
of the heatingor cooling equipmentrunning until the desired setpointis reached. Recommendedsettingfor Geothermal Heat
Pumpsto allowthe 100p to rest.
Backup
heat differential
and upstage
timer
A backup
heat differential
and backup
heat
upstage
timer
can be set on any
system
that has more
than
one type
of heating
equipment.
See installer
setup
options
(ISU 3070-3110).
Normal
operation
When
the Backup
Heat
Differential
is set to Comfort,
the thermostat
uses
backup
heat
as needed
to keep
the indoor temperature
within
1 o F (0.5 ° C) of the set-
point.
If the Backup
Heat
Upstage
Timer
is used,
the thermostat
delays
the back-
up heat
from
turning
on until the timer
expires.
When
the Backup
Heat
Differential
is set to 2 ° F or higher,
backup
heat
is not
used
unless
the indoor
temperature
drops
to the Backup
Heat Differential
setting
or the Backup
Heat
Upstage
Timer expires.
The upstage
timer
starts
when
the
highest
stage
of the previous
equipment
type
turns
on.
Manual
temperature
change
When
the Backup
Heat
Differential
is set to Comfort,
the thermostat
uses
backup
heat
as needed
to keep
the indoor
temperature
within
1 o F (0.5 ° C) of the set-
point.
When
the Backup
Heat
Differential
is set to 2 ° F or higher,
if the primary
heat
is
making
progress
as expected,
backup
heat witl not be used
to reach
the new
setpoint.
Set to a higher
number
to use less backup
heat
(a greater
difference
between
the current
indoor temperature
and the new setpoint
is required
to turn
on backup
heat).
See note
below.
Programmed
recovery
If the primary
heat
is making
progress
as expected,
backup
heat
will not be used
to reach
the setpoint
of the next
program
period.
Backup
heat is atway_
restrict=
ed during
a programmed
recovery
when
the Adaptive
Intelligent
Recovery
feature
is used.
Set the Backup
Heat Differential
to a higher
number
to use less
backup
heat.
See note
below.
During a programmedrecovery(or when the temperature setpointis changedby the user), the thermostat waitsto turn on the
backup heat dependingon system performance,load conditionsand how manydegreesthe temperaturesetpoint is changed.
Backup heatwill be used ONLYwhen the temperature is not rising quickly enough to reach the setpoint in a reasonabletime.
69-2490--03
20